Region

Introducing

Phenomenex bioZen LC Columns

for Biologics Analysis

Phenomenex bioZen Information


  • Explore a New State of Zen for:
  • Peptide Mapping Aggregate Analysis Glycan Analysis Peptide Quantitation Drug Antibody Ratio Intact Mass Intact and Fragment Analysis
 
Ti Biocompatible Titanium Frit
 
Traditional Stainless Steel
 
Ti Biocompatible Titanium

Introducing Phenomenex Biozen HPLC/UHPLC Columns

With a new titanium hardware to minimize priming, four particle platforms for optimal versatility and nine particle chemistries to maximize selectivity and sensitivity, Biozen UHPLC/HPLC columns are seamlessly designed to bring peace of mind to your

  • Aggregate Analysis

    Quantitation of aggregate is a critical quality attribute in biopharmaceutical development. The determination of monomer, dimer, and multimer, as well as higher order structure (quaternary structural determination of a mAb), and high/low molecular weight species are commonly observed through size exclusion chromatography.

  • Drug Antibody Ratio (DAR)

    The average drug-to-antibody ratio (DAR) is critical to assess in the development of antibody-drug conjugates (ADCs). Though different chromatography modes can be employed to determine DAR, a highly effective method utilized reversed phase chromatography.

  • Glycan Analysis

    Glycosylation of proteins-specifically monoclonal antibodies-have indications on protein structure and is arguably the most critical post-translational modification to characterize in biopharmaceutical development. N-glycan analysis through hydrophilic interaction chromatography (HILIC) is a robust method for absolute quantitation of glycoforms and is the gold standard for glycosylation characterization.

  • Intact Mass

    Intact mass analysis involves using high resolution accurate mass (HRAM) instrumentation to confirm protein sequence and identify post-translational modifications. Often in combination with reversed phase chromatography, intact mass analysis is utilized on native proteins, mAbs, and ADCs in biopharmaceutical development.

  • Intact and Fragment Analysis

    Observation of intact protein and fragmented protein during impurity profiling is essential in biologic development. Utilizing reversed phase chromatography on native protein and partially fragmented protein scientists can observe characteristics including heavy chain/light chain, Fc/Fab, or isoforms.

  • Peptide Mapping

    For protein characterization, peptide mapping is commonly used for identification of non-enzymatic, spontaneous post translational modifications, such as deamidation, oxidation, succinimide formation, pyroglutamate formation, and others. Reversed phase chromatography is used for confirming primary sequence, but is more commonly for PTM identification.

  • Peptide Quantitation

    The determination of signature peptide concentration from biological matrices using LC-MS. Scientists utilize peptide quantitation to deconvolute complex chromatograms by searching for specific peptide sequences, which can analyze the peptides with high sensitivity and specificity, even at low levels of peptide.

  • Charge Variant Analysis (IEX)

    Separate MABs from from acidic/basic variants .

  • Whether you are working with
  • novel proteins

    Complex large molecules composed of amino acid polymer chains. Proteins in biopharmaceuticals typically range from 3,000-150,000 kDa. Under the biologics classification, biopharmaceutical proteins can be hormones, human growth factors, and monoclonal antibodies (mAbs). The most common biopharmaceutical proteins are insulin and mAbs.

  • or biosimilars

    A biologic with the same sequence and similar function to an innovator biologic. The characterization of biosimilars requires the same chromatographic techniques as its corresponding innovator biologic

  • Biozen UHPLC columns are guaranteed
  • to help you analyze large biologics. Explore bioZen Nano LC Columns: Focus, Fractionate, and Trap!
biozen nano LC columns

Biozen 0.075mm ID columns allow for minimized band broadening and improved analyte focusing for increased sensitivity for separation of omics. biozen 0.075mm ID columns are available in the following phases and particle sizes:

  • 3µm PS-C18
  • 3µm Polar C18
  • 2.6µm XB-C18

Introducing Biozen NX-C18 phase for robust, reproducible, high pH fractionation. bioZen NX-C18 columns offre high efficiency and reproducible performance in comparsion to traditional fractionation columns on the market

biozen LC columns
biozen nano LC traps

Biozen trap columns are the perfect fit for your 0.075mm ID nano LC columns and are available in both a general reverse phase and aqueous stable reversed phase selectivities.

Intact XB-C8


Intact XB-C8 Phase Information


Large pore core-shell particle for fast intact biologic entry. C8 provides highly useful moderate hydrophobic selectivity.

Document Type:
Document Type Title
Brochures 2022/2023 色谱产品指南 (Catalog) Add to My Documents
Technical Notes Aggregate Analysis of an IgG2 Monoclonal Antibody using a Biozen dSEC-2 LC Column Add to My Documents
Technical Notes Aggregate Analysis of Fc-Fusion Proteins using a Biozen dSEC-2 LC Column Add to My Documents
Technical Notes Assessing Column Lifetime of a UHPLC Size Exclusion Column using a Biozen dSEC-2 LC Column Add to My Documents
Brochures Biocompatible Hardware Brochure Add to My Documents
Brochures Biologics Workflow: Aggregate Analysis (bioZen SEC Columns) Add to My Documents
Technical Notes bioZen 2.6 μm Nano Peptide XB-C18 Column Core-shell Technology Results in Improved Peptide Identifications in HeLa Cell Lysates in Comparison to Competitor Brands With and Without a Nano-Trap Column Add to My Documents
Supporting Docs bioZen Column Care Note Add to My Documents
Brochures Biozen dSEC Application Guide Add to My Documents
Brochures Biozen dSEC Column Product Guide Add to My Documents
Supporting Docs Biozen dSEC-2 FAQ flyer Add to My Documents
Brochures bioZen FAQ Brochure Add to My Documents
Brochures bioZen Product Guide Add to My Documents
Technical Notes bioZen Tech Tip: Deglycosylation Add to My Documents
Technical Notes bioZen Tech Tip: Drug-Antibody Ratio (DAR) Add to My Documents
Technical Notes bioZen Tech Tip: Intact Mass Add to My Documents
Technical Notes bioZen Tech Tip: Loading Capacity for SEC and Reversed Phase HPLC/UHPLC Add to My Documents
Technical Notes bioZen Tech Tip: N-Glycan Analysis Add to My Documents
Technical Notes bioZen Tech Tip: Organic Solvent and Size Exclusion Add to My Documents
Technical Notes bioZen Tech Tip: Peptide Mapping Add to My Documents
Technical Notes bioZen Tech Tip: Size Exclusion and a Well Salted Buffer Add to My Documents
Supporting Docs Biozen dSEC-2 Guard column Flyer Add to My Documents
Technical Notes Column Reproducibility and Robustness using the bioZen Nano 2.6 μm XB-C18 LC Column Add to My Documents
Technical Notes Comparison of Polymeric and Silica-Based Columns for Oligonucleotide Analysis by Ion-Pair Reversed Phase Add to My Documents
Technical Notes Coupling Minaturized SPE with bioZen XB-C18 Nano Core-Shell Technology for the Detection of SARS-CoV-2 Nucelocapsid Protein Viral Peptides in Nasopharyngeal Samples Add to My Documents
Technical Notes Deep Proteome Coverage on HeLa Lysate using a bioZen™ Fractionation Column for High pH (Basic Reversed Phase) Fractionation in Combination with a bioZen Nano Peptide XB-C18 Column for Nano Flow LC-MS Add to My Documents
Technical Notes Determining Trap Loadability using the bioZen™ 3 μm Polar C18 Nano Column in Conjunction with the bioZen RP1 Nano Trap Column (TN-1277) Add to My Documents
Technical Notes Effect of Different Column Lengths in SEC using Biozen dSEC 2 Columns Add to My Documents
Technical Notes Effect of Mobile Phase pH in Aggregate Analysis of Monoclonal Antibodies by Size Exclusion Chromatography using a Biozen dSEC-2 LC Column Add to My Documents
Technical Notes Effect on Resolution in SEC Comparing Different Particle Sizes and Column Sizes of Biozen dSEC-2 Columns Add to My Documents
Technical Notes Going from Small to Tiny: Increasing Sensitivity by Scaling Down from Micro to Nano Flow LC (TN-1278) Add to My Documents
Technical Notes Guard Column Lifetime and Capacity to Protect the Biozen ™dSEC 2 Column Add to My Documents
Technical Notes Heat and High pH Forced Degradation of Antibodies on a Biozen dSEC-2 Column Add to My Documents
Technical Notes Improved Sensitivity and Recovery Using a Biozen dSEC-2 Column Add to My Documents
Technical Notes Investigating the Influence of Selectivity in bioZen Nano Column and Trap in Bottom Up Proteomics (TN-1282) Add to My Documents
Technical Notes Loading capacity of Biozen dSEC-2 Column Under SEC-HRMS Conditions Add to My Documents
Technical Notes Method Development for ADC Kadcyla by Size Exclusion LC Using a Biozen ™dSEC 2 Column Add to My Documents
Technical Notes Number of Protein and Peptide Identifications for the bioZen™ Nano 2.6 μm XB-C18 LC Column in HeLa Lysate Add to My Documents
Technical Notes Oligonucleotide Analysis by Size Exclusion Using a Biozen dSEC-2 Column Add to My Documents
Technical Notes Resiliency of Larger Particle Sizes to Systems of Differing Dwell Volume in SEC using Biozen dSEC 2 Column Add to My Documents
Brochures SEC Chromatographic Solution in Aggregate Analysis Add to My Documents
Technical Notes Size Exclusion Analysis Following IdeS Digestion Using a Biozen dSEC-2 Column Add to My Documents
Brochures Biozen dSEC Aggregate Solution Analysis Japanese Add to My Documents
Brochures Biozen dSEC Column Product Guide Japanese (Biozen dSEC  カラム製品ガイド) Add to My Documents
Phase: Particle Size: Pore Size: Length: Internal Diameter:
Loading...

Part Number:

Description:

Required Holder:

Stationary Phase:

Solid Support:

Format:

Separation Mode:

Recommended Use:

USP Designation:


 Search Results


Part
Number
Brand Phase Particle
Size (µm)
Pore
Size (Å)
Length (mm) Internal
Diameter (mm)
Price