;
Region

Zebron GC Information


Zebron Phases

Get More Than Just A Column

Customers Come First

VIDEO: Our Quality

 

 

ZB-DHA-PONA Phase Detail


ZB-DHA-PONA Phase Information


The Optimal Choice for PIONA, DHA and PONA:

Zebron ZB-DHA-PONA is the optimal choice for the analysis of Detailed Hydrocarbon Analysis (DHA) within the Fuel industry. It’s unique Engineered Self Cross-linking™(ESC) stationary phase provides low bleed and exceptional column life for optimal separation of DHA critical pairs with symmetric peaks. In addition, Zebron ZB-DHA-PONA GC columns provide excellent response and peak symmetry for polar oxygenates.

Zebron Column Cross-Section
  • Excellent peak shape for polar & nonpolar compounds
  • Temperature stability & flexibility
  • Highly efficient dimension and consistent film thickness delivers excellent separation of Paraffins, Iso-paraffins, Olefins, Naphthenes, Aromatics and polar compounds
  • Extensive ESC™ provides intact stationary phase and MS certified low bleed
  • Well-suited for true boiling point separation
  • Excellent resolving power for critical pairs in complex petrochemical samples

Recommended For: DHA Analysis, PONA, PIONA, PIANO, ASTM D5134, D5441, D5501, D6729, D6730 and D6733

Easy ZB-DHA-PONA selection for your ASTM method:

Method Description Recommended Column Recommended Dimensions Phenomenex Part Number
ASTM D5134 Standard Test Method for Detailed Analysis of Petroleum Naphtha's through n-Nonane by Capillary Gas Chromatography ZB-DHA-PONA 50m x 0.20mm x 0.5µm 7JE-G042-17
ZB-DHA-PONA 100m x 0.25mm x 0.5µm 7MG-G042-17
ASTM D5441 Standard Test Method for Analysis of Methyl Tert-Butyl Ether (MTBE) by GC ZB-DHA-PONA 50m x 0.20mm x 0.5µm 7JE-G042-17
ZB-DHA-PONA 100m x 0.25mm x 0.5µm 7MG-G042-17
ZB-DHA-PONA 150m x 0.25mm x 1µm 7QG-G042-22
ASTM D5501 Standard Test Method for Determination of Ethanol and Methanol Content in Fuels Containing Greater than 20% Ethanol by Gas Chromatography ZB-DHA-PONA 100m x 0.25mm x 0.5µm 7MG-G042-17
ZB-DHA-PONA 150 m x 0.25 mm x 1 µm 7QG-G042-22
ASTM D6729 Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High Resolution Gas Chromatography ZB-DHA-PONA 100m x 0.25mm x 0.5µm 7MG-G042-17
ASTM D6730 Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary (with Precolumn) High Resolution Gas Chromatography ZB-DHA-PONA 50m x 0.20mm x 0.5µm 7JE-G042-17
ZB-DHA-PONA 100m x 0.25mm x 0.5µm 7MG-G042-17
ZB-DHA-PONA 150m x 0.25mm x 1µm 7QG-G042-22
ZB-DHA-PONA-TUNE 5m x 0.25mm x 1µm 7AG-G042-22
ASTM D6733 Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High Resolution Gas Chromatography ZB-DHA-PONA 50m x 0.20mm x 0.5µm 7JE-G042-17
Document Type:
Document Type Title
Brochures 2022/2023 色谱产品指南 (Catalog) Add to My Documents
Technical Notes A Simple and Rapid Extraction Method for Chlorinated Pesticides from poultry fat using SPE and GCECD (TN-0090) Add to My Documents
Technical Notes Drugs of Abuse Panel from Urine by GC/MS and LC/MS (TN-0041) Add to My Documents
Technical Notes Analysis of 33 Primary and Secondary Terpenes Found in Cannabis by GC-FID Add to My Documents
Technical Notes Analysis of Sensory-Active Volatile Phenols in Smoke-Exposed Grapes by Gas Chromatography (TN-2068) Add to My Documents
Brochures Analyzing Fats and Oils by GC Add to My Documents
Brochures Cannabis Testing Guide Add to My Documents
Brochures Custom Method Development and Optimization Services for Clinical Research Add to My Documents
Other Environmental Testing Guide Add to My Documents
Other Essential Guide for Biofuel Analysis Add to My Documents
Technical Notes Endothalls in Water by EPA Method 548.1 using SPE and GC/MS (TN-0067) Add to My Documents
Technical Notes Extraction and Analysis of THC and Metabolites from Whole Blood and Urine by GC/MS (TN-2062) Add to My Documents
Technical Notes Fast Analysis of 24 Regulated PAHs on a Zebron™ ZB-PAH GC Column (TN-2070) Add to My Documents
Brochures Food Testing Sample Preparation Guide Add to My Documents
Brochures Gas Management Trifold Add to My Documents
Brochures GC Accessories: Product Overview Guide Add to My Documents
Other Zebron GC Column Selection Poster Add to My Documents
Brochures GC Environmental Selection Guide Add to My Documents
Brochures GC Food Testing Guide Add to My Documents
Supporting Docs GC Resources Flyer Add to My Documents
Other GC Troubleshooting Guide Add to My Documents
Technical Notes GC/MS Analysis of PAHs in Rubber and Plastic (TN-2071) Add to My Documents
Other Guide To GC Column Care Add to My Documents
Other How To Choose A 5 Phase Column Add to My Documents
Technical Notes Improved Analysis of EPA Method 625 Using Large- Particle, Large-Pore Solid Phase Extraction (SPE) (TN-0091) Add to My Documents
Technical Notes Improved Analysis of EPA Method 8270D (TN-2049) Add to My Documents
Technical Notes Improved Analysis of Flavor Compounds In Scotch Whiskey Using An Aqueous-Stable Polyethylene Glycol Stationary Phase Add to My Documents
Technical Notes Improving the Analysis of European Union (EU) PAHs using a Zebron™ ZB-PAH GC Column (TN-2072) Add to My Documents
Brochures Kinetex PAH and Zebron ZB-PAH Product Guide Add to My Documents
Brochures Pesticide Analysis by GC/LC/Sample Prep Add to My Documents
Other Pharmaceutical Analysis Guide- Formulations Add to My Documents
Technical Notes Polycyclic Aromatic Hydrocarbons (PAHs) in Tattoo Ink by GC/MS (TN-2066) Add to My Documents
Technical Notes BTEX by GC (TN-2001) Add to My Documents
Technical Notes Organic Compounds Analysis in Drinking Water (EPA 525.2) by GC (TN-2004) Add to My Documents
Technical Notes VOA Analysis (EPA 8260B) by GC (TN-2005) Add to My Documents
Technical Notes PONA Analysis on Gasoline Fractions by GC (TN-2006) Add to My Documents
Technical Notes Enhanced Results of Diesel Range Organics (DROs) (TN-2015) Add to My Documents
Technical Notes Considerations for Using Narrow Bore (0.10 mm) GC Columns (TN-2015) Add to My Documents
Technical Notes A Simple Guide to Improving GC Column Lifetime (TN-2017) Add to My Documents
Technical Notes Considerations When Optimizing Your GC Method: Phase Ratio (TN-2018) Add to My Documents
Technical Notes The Importance of System Conditioning After Installing a New Gas Chromatography Column (TN-2019) Add to My Documents
Technical Notes Troubleshooting Problems When Lighting a GC/FID (TN-2020) Add to My Documents
Technical Notes Multi-Residue Pesticide Screening by GC/MS (TN-2021) Add to My Documents
Technical Notes Diesel Fractionation by GC Following the Revised Massachussets EPH Guidelines (TN-2022) Add to My Documents
Technical Notes Aqueuos Stability for Distilled Spirits Testing by GC (TN-2025) Add to My Documents
Technical Notes Chlorinated Pesticides by GC (EPA 8081) (TN-2026) Add to My Documents
Technical Notes Polyaromatic Hydrocarbons (PAHs) by GC (TN-2027) Add to My Documents
Technical Notes Understanding the Revisions to USP Monograph <467>: Residual Solvents (TN-2028) Add to My Documents
Technical Notes Accurate and Painless GC Column Installation (TN-2029) Add to My Documents
Technical Notes Glycerin in Biodiesel Using a High Temperature Fused Silica GC Column (TN-2030) Add to My Documents
Technical Notes Split Injections in Gas Chromatography: How to Reduce Inlet Discrimination By Using a Liner with Glass Wool (TN-2031) Add to My Documents
Technical Notes Revised USP Chapter 467 and its Application to Excipient Qualification and Testing (TN-2032) Add to My Documents
Technical Notes Bioethanol Analysis by GC Following ASTM Method D 5501 (TN-2033) Add to My Documents
Technical Notes Blood Alcohols by GC (TN-2036) Add to My Documents
Technical Notes 2 Ways to Attain Sharper Peak Shape and Higher Sensitivity in Gas Chromatography (TN-2038) Add to My Documents
Technical Notes Chlorinated Pesticides by GC/ECD (TN-2039) Add to My Documents
Technical Notes Opiates from Urine by GC/MS and LC/MS/MS (TN-2040) Add to My Documents
Technical Notes Blood Alcohol Internal Standard Selection for Post Mortem Samples by GC (TN-2041) Add to My Documents
Technical Notes Easy and Painless GC Column Installation (TN-2042) Add to My Documents
Technical Notes Simulated Distillation (ASTM D6352 and D71679) by GC (TN-2043) Add to My Documents
Technical Notes Blood Alcohol Analysis by Resolution of Propanol from Ethanol by GC (TN-2044) Add to My Documents
Technical Notes Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC (TN-2045) Add to My Documents
Technical Notes Gulf Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS (TN-2046) Add to My Documents
Technical Notes EPA Method 8270D by GC (TN-2050) Add to My Documents
Technical Notes Diesel Range Organics Analysis by High Temperature GC (TN-2051) Add to My Documents
Brochures Zebron ZB-5MSplus GC Columns Add to My Documents
Brochures ZB-FAME, The Fast FAME GC Column Add to My Documents
Brochures Zebron 5 Phase Selection Add to My Documents
Brochures Zebron ZB-1XT SimDist GC Columns Add to My Documents
Brochures Zebron ZB-CLPesticides GC Columns Add to My Documents
Brochures Zebron ZB-SemiVolatiles GC Columns Add to My Documents
Brochures Zebron ZB-WAXplus GC Columns Add to My Documents
Technical Notes 37 FAMEs including Omega-3 and -6 Fatty Acids by GC-FID in Under 12 Minutes (TN-2069) Add to My Documents
Brochures Advanced Pesticide Testing Using Zebron GC Columns Add to My Documents
Brochures GC Accessories: Cool-Lock Installation Nut Add to My Documents
Technical Notes Determination of Sterols in Olive Oil (TN-0114) Add to My Documents
Technical Notes Drugs of Abuse Analysis by GC/MS using a Zebron ZB-5MSplus Add to My Documents
Brochures GC Accessories: Easy Seals Inlet Base Seals Add to My Documents
Technical Notes Environmental Contaminants from Oil Spills (TN-2045) Add to My Documents
Technical Notes Ethanolamine Analysis by GC/MS using a Zebron ZB-5MSplus Add to My Documents
Technical Notes Extraction and GC/MS Analysis of Cannabinoids from Brownies using roQ QuEChERS Extraction Salts and a Zebron ZB-5MSplus GC Column Add to My Documents
Technical Notes Extraction and GC/MS Analysis of Melamine From Dog Food using a Zebron ZB-5MSplus GC column Add to My Documents
Technical Notes Haloacetic Acids from Water by GC/ECD (TN-0039) Add to My Documents
Technical Notes Fast Analysis of 37 FAMEs in 11 Minutes Using a Zebron ZB-FAME GC Column Add to My Documents
Brochures GC EPA Application Guide Add to My Documents
Technical Notes Polycyclic Aromatic Hydrocarbons (PAHs) by GC/MS and LC/MS (TN-0042) Add to My Documents
Technical Notes Improved Resolution of Triazine Herbicides (TN-2052) Add to My Documents
Technical Notes Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS (TN-2046) Add to My Documents
Technical Notes Optimized Analysis of 1,4-Dioxane in Tap Water by GC/MS (TN-2065) Add to My Documents
Technical Notes Optimized Column Selectivity for Orthogonal Separation of Fatty Acid Methyl Esters (FAMEs) Using GCxGC (TN-2064) Add to My Documents
Technical Notes Polycyclic Aromatic Hydrocarbons (PAH) in Electronic Components using Zebron™ ZB-PAH by GC-MS (TN-2073) Add to My Documents
Technical Notes Quick, Accurate Testing of FAMEs in Olive Oil by GC/FID Using a Zebron™ ZB-FAME GC Column (TN-2063) Add to My Documents
Technical Notes Melamine and Cyanuric Acid by LC/MS/MS (TN-0021) Add to My Documents
Technical Notes Converting from Packed to Capillary GC Columns (TN-2016) Add to My Documents
Technical Notes Polychlorinated Biphenyls (PCBs) Designated as Toxic by the World Health Organization (WHO) by GC/MS (TN-2023) Add to My Documents
Technical Notes The Effect of Temperature on Compound Elution Order in GC (TN-2034) Add to My Documents
Technical Notes Single-Run Analysis of PBDEs Including BDE-209 on Zebron ZB-SemiVolatiles (TN-2054) Add to My Documents
Technical Notes EPA Method 508.1 with Automated Extraction by GC/ECD (TN-0050) Add to My Documents
Brochures Zebron ZB-MultiResidue GC Columns Add to My Documents
Brochures Zebron Essentials for FAMEs, Smart Alternatives for the FAMEs Traditionalist Add to My Documents
Brochures Zebron PLUS GC Inlet Liners Add to My Documents
Technical Notes 37 FAMEs In Under 25 Minutes by GC/FID Using Zebron ZB-FAME Add to My Documents
Technical Notes FAMEs In Monterey Jack Cheese by GC/FID Using Zebron ZB-FAME Add to My Documents
Technical Notes FAMEs In Peanut Butter by GC/FID Using Zebron ZB-FAME Add to My Documents
Technical Notes FAMEs in Soybean Oil by GC/FID Using Zebron™ ZB-FAME Add to My Documents
Brochures GC Inlet Liners Add to My Documents
Brochures GC Method Development GUide Add to My Documents
Brochures Zebron Inferno GC Columns Add to My Documents
Brochures Zebron ZB-Bioethanol GC Columns Add to My Documents
Phase: Length: Internal Diameter: Film Thickness: Composition: Min Temp (C): Max Temp – TPGC (C):
Loading...

Part Number:7MG-G042-17

Description:Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5um , Ea

Composition:Proprietary Pesticides Phase

Recommended Use:

Composition:Composition

Temp.Limits(C):

Polarity:

MS Certified:

USP Designation:

Recommended Use:

     Search Results


    Part
    Number
    Brand Phase Length (m) Internal
    Diameter (mm)
    Film
    Thickness (µm)
    Price